Simultaneous spectrophotometric determination of nitroaniline isomers after cloud point extraction by using

Ali Niazi1, Jahanbakhsh Ghasemi, Ateesa Yazdanipour

  • 1Chemistry Department, Faculty of Sciences, Azad University of Arak, Arak, Iran. ali.niazi@gmail.com

Related Concept Videos

Precipitation Titration: Endpoint Detection Methods01:19

Precipitation Titration: Endpoint Detection Methods

In argentometric precipitation titrations, endpoints can be detected visually by the Mohr, Volhard, and Fajans methods. In the Mohr method, adding a soluble chromate indicator gives an initial yellow color to the analyte solution. As the titrant is added, the first excess of silver ions forms a red silver chromate precipitate, marking the endpoint. The solution pH should be maintained at about 8 by adding solid CaCO3.
In the Volhard method, a standard excess of AgNO3 is first added to the...
Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Precipitation Titration: Overview01:26

Precipitation Titration: Overview

Precipitation titration involves the reaction of a titrant and an analyte to generate an insoluble precipitate. While precipitation titration uses various precipitating agents, silver nitrate is the most common precipitating reagent; titrations involving Ag+ are called argentometric titrations. Usually, the endpoint in a precipitation titration can be detected by visual indicators.
A precipitation titration curve demonstrates the change in concentration of the titrant or analyte upon adding the...
Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
NMR Spectroscopy Of Amines01:19

NMR Spectroscopy Of Amines

In proton NMR spectroscopy, primary amines and secondary amines showcase their N–H protons as a broad signal in the chemical shift range between δ 0.5 and 5 ppm. The exact position in this range depends on several factors, including sample concentration, hydrogen bonding, and the type of solvent used. Since amine protons undergo fast proton exchange in solution, the protons are labile and therefore do not participate in any splitting with adjacent protons. Thus, the observed peak is broad and...
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations01:08

IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations

Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single stretching vibration...