Related Experiment Video
Updated: Jul 16, 2026

Ex Vivo Porcine Experimental Model for Studying and Teaching Lung Mechanics
Published on: April 19, 2024
Effects of open endotracheal suction on lung volume in infants receiving HFOV
D G Tingay1, B Copnell, J F Mills
1Department of Neonatology, Royal Children's Hospital, Flemington Rd, 3052, Parkville, VIC, Australia. david.tingay@rch.org.au
Objective:
To describe the pattern and magnitude of lung volume change during open endotracheal tube (ETT) suction in infants receiving high-frequency oscillatory ventilation (HFOV).
Design:
Prospective observational clinical study.
Setting:
Tertiary neonatal intensive care unit.
Patients And Participants:
Seven intubated and muscle-relaxed newborn infants receiving HFOV.
Interventions:
Open ETT suction was performed for 6 s at -100 mmHg using a 6-F catheter passed to the ETT tip after disconnection from HFOV. The HFOV was then recommenced at the same settings as prior to ETT suction.
Measurements And Results:
Change in lung volume (DeltaV (L)) referenced to baseline lung volume before suction was measured with a calibrated respiratory inductive plethysmography recording from 30 s before until 60 s after ETT suction. In all infants ETT suction resulted in significant loss of lung volume. The mean DeltaV (L) during suctioning was -13 ml/kg (SD 4 ml/kg) (p<0.0001 vs. baseline, repeated-measures ANOVA), with a mean 76.5% (SD 14.1%) of this volume loss being related to circuit disconnection. After recommencing HFOV lung volume was rapidly regained with mean DeltaV (L) at 60 s being 1 ml/kg (SD 4 ml/kg) below baseline (p>0.05, Tukey post-test).
Conclusions:
Open ETT suction caused a significant but transient loss of lung volume in muscle-relaxed newborn infants receiving HFOV.
Related Concept Videos
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Tracheostomy Suctioning II: Procedure
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...