A kinetic method amenable to automation for ceruloplasmin estimation with inexpensive and stable reagents
Babu Lal Somani1, Vivek Ambade
1Department of Biochemistry, Armed Forces Medical College, Pune-411040, India. blsomani@gmail.com
Objectives:
To develop a kinetic, inexpensive, automatable assay for ceruloplasmin as ferroxidase.
Design And Methods:
Dithiothreitol has been used to stabilize the substrate and quinolones to complex the ferric.
Results:
Mean ferroxidase activity in healthy adults, Wilson's disease and pregnancy was 787.29, 178.5 and 1828.09 IU/L, respectively. Correlation coefficient of ferroxidase vis-à-vis copper, ferroxidase by ferrozine and ceruloplasmin were 0.90, 0.94 and 0.92, respectively.
Conclusions:
Norfloxacin method is a simple, inexpensive and automatable kinetic assay.
More Related Videos
05:36Quantifiable and Inexpensive Cell-Free Fluorescent Method to Confirm the Ability of Novel Compounds to Chelate Iron
Published on: February 23, 2024
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
Related Concept Videos
Controlled-Current Coulometry: Coulometric Titration
The fundamental requirements for coulometric titrations are (1) 100% efficiency in the reagent-generating electrode reaction and (2) a stoichiometric and preferably rapid reaction between the generated...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.