Related Experiment Video
Updated: Jan 19, 2026

Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
Development and evaluation of porous dental implants in miniature swine
Abstract:
Organized bone ingrowth in endosteal porous implants fabricated from VMC titanium alloy and surgically implanted with a tight interference fit, securely anchored the implants in fresh and healed mandibular premolar sites of miniature swine. This bone-implant union retained its integrity under high as well as slight masticatory stresses up to one-year after implantation. Bone invasion of the alumina porcelain implants was impeded by the lack of adequate interconnecting porosity; when the porosity was increased, insufficient ceramic strength prohibited a tight initial bone-implant fit. As a consequence, inadequate initial implant stability resulted in a soft tissue encapsulation of the majority of the ceramic implants. Histological examination and mechanical testing results were similar for bone-ingrown implants exposed to different experimental stresses for 4, 5, 8, and 12 months. Bone ingrowth and interface shear strengths were also similar in the different VMC pore sizes and shapes investigated. The design of intraoral attachments appeared critical, at least in swine where no postoperative treatment was administered. Gingival inflammation and alveolar bone resorption caused by calculus were severe around truncated cone-shaped devices. Slender transgingival posts, occlusal caps, and crown restorations were less susceptible to calculus accumulation, resulting in a more satisfactory gingival and subgingival response. Excessive epithelial invagination was a problem only in implants with transgingival truncated cones. Good adherence of soft tissue to metal under the gingival mucosa prevented epithelial migration around implants with other transgingival devices. Alveolar bone resportion around the tops of bone-ingrown implants was minimal at the time intervals examined (up to one year); however, a definite conclusion should be delayed until longer-term implants under full occlusion are evaluated.
Related Concept Videos
05:42Dynamic Navigation for Dental Implant Placement
06:16The Miniature Pig: A Large Animal Model for Cochlear Implant Research
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
11:19Oral Biofilm Formation on Different Materials for Dental Implants
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
09:29Fabrication and Implantation of Miniature Dual-element Strain Gages for Measuring In Vivo Gastrointestinal Contractions in Rodents.

