Related Experiment Video
Updated: Jul 16, 2026

Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Hemodynamic and functional assessment of patients with sickle cell disease and pulmonary hypertension
Anastasia Anthi1, Roberto F Machado, Maria L Jison
1Vascular Medicine Branch, Clinical Center, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 2089, USA.
Rationale:
Although pulmonary hypertension (PH) is a common complication of sickle cell disease (SCD) associated with high mortality, there exist few data characterizing hemodynamics and cardiopulmonary function in this population.
Objectives:
To characterize hemodynamics and cardiopulmonary function in patients with SCD with and without PH.
Methods:
Patients with SCD with PH (n = 26) were compared with control subjects with SCD but without PH (n = 17), matched for age, hemoglobin levels, and fetal hemoglobin levels.
Measurements And Main Results:
Upon catheterization, 54% of the patients with PH had pulmonary arterial hypertension, and 46% had pulmonary venous hypertension. When compared with control subjects, patients with PH exhibited lower six-minute-walk distance (435 +/- 31 vs. 320 +/- 20 m, p = 0.002) and oxygen consumption (50 +/- 3% vs. 41 +/- 2% of predicted, p = 0.02), and also had mild restrictive lung disease and more perfusion abnormalities on radionuclide lung scans. The six-minute-walk distance in this population inversely correlated with tricuspid regurgitant jet velocity (r = -0.55, p < 0.001), and mean pulmonary artery pressure (r = -0.57, p < 0.001), and directly correlated with maximal oxygen consumption (r = 0.49, p = 0.004), even after adjustment for hemoglobin, supporting an independent contribution of increasing pulmonary artery pressures to loss of exercise capacity.
Conclusions:
Patients with SCD-associated PH have both pulmonary arterial and venous PH associated with severe limitations in exercise capacity, likely compounded by interstitial lung fibrosis and severe anemia. These data support the use of the six-minute-walk distance as an index of PH and cardiopulmonary function in patients with SCD.
Related Concept Videos
Mitral Stenosis IV: Nursing Management
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Heart Failure VI: Adjunct Therapies
Heart Failure V: Medical Management
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...

