Related Experiment Video
Updated: Jul 16, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Comparison of work of breathing using drawover and continuous flow anaesthetic breathing systems in children
G T Bell1, J P J McEwen, S J Beaton
1Royal Hospital for Sick Children, Yorkhill, Glasgow, G3 8SJ, UK. graham.bell@yorkhill.scot.nhs.uk
Abstract:
We compared the work of breathing under general anaesthesia in children using drawover and continuous flow anaesthetic systems. A pilot study was conducted in four children weighing > 20 kg in whom it would usually be considered appropriate to use breathing systems designed for adult anaesthesia. The pilot study compared work of breathing using the Mapleson D breathing system and the Triservice Anaesthetic Apparatus (TSAA). Work of breathing was calculated using the modified Campbell technique that calculates work using a pressure volume loop derived from oesophageal pressure and airway gas volume measurements. We found no difference in the work of breathing when comparing the Mapleson D and the TSAA in children > 20 kg. Following completion of the pilot study, we conducted a study on 10 children weighing between 10 and 20 kg comparing work of breathing using the Mapleson F breathing system and the TSAA. We found no significant difference in the work of breathing between the Mapleson F and the TSAA for these children. The TSAA can therefore be recommended for use down to a lower weight limit of 10 kg.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.