Related Experiment Video
Updated: Jul 16, 2026

Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Fingerprint developing of coffee flavor by gas chromatography-mass spectrometry and combined chemometrics methods
Lan-Fang Huang1, Ming-Jian Wu, Ke-Jun Zhong
1College of Chemistry and Chemical Engineering, Central South University, Changsha 10083, China. lf18huang@yahoo.com.cn
Abstract:
In this paper, chromatographic fingerprint was firstly used for quality control of tobacco flavors. Based on gas chromatography-mass spectrometry (GC-MS) and combined chemometrics methods, a simple, reliable and reproducible method for developing chromatographic fingerprint of coffee flavor, one of tobacco flavors, was described. Six coffee flavor samples obtained from different locations were used to establish the fingerprint. The qualitative and quantitative analysis of coffee flavor sample from Shenzhen was completed with the help of subwindow factor analysis (SFA). Fifty-two components of 68 separated constituents in coffee flavor sample from Shenzhen, accounting for 88.42% of the total content, were identified and quantified. Then, spectral correlative chromatography (SCC) was used to extract the common peaks from other five studied coffee flavor samples. Thirty-eight components were found to exist in all six samples. Finally, the method validation of fingerprint analysis was performed based on the relative retention time and the relative peak area of common peaks, sample stability and similarity analysis. The similarities of six coffee flavor samples were more than 0.9104 and showed that samples from different locations were consistent to some extent. The developed chromatographic fingerprint was successfully used to differentiate coffee flavor from cocoa flavor and some little difference sample prepared with coffee flavor and cocoa flavor by both similarity comparison and principal component projection analysis. The developed method can be used for quality control of coffee flavor.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...