Dynamic Digital Biomarkers of Motor and Cognitive Function in Parkinson's Disease
Published on: July 24, 2019
Blood pressure and heart rate in parkinsonian patients with and without wearing-off
V Pursiainen1, J T Korpelainen, T H Haapaniemi
1Department of Neurology, University of Oulu, Oulu, Finland. ville.pursiainen@sci.fi
Abstract:
Our study aimed to investigate the cardiovascular autonomic regulation related to the wearing-off phenomenon in Parkinson's disease (PD). We measured blood pressure (BP) and heart rate (HR) at rest and during orthostatic test in 16 patients with PD with wearing-off and in 15 patients with PD without wearing-off both before (baseline) and repetitively at 1-h intervals for up to 4 h after the morning PD medication dose. The patients with wearing-off had fluctuation of BP during the observation period, BP increasing when the motor performance worsened and vice versa. The mean supine BP was at its highest at the baseline measurement (patients with wearing-off, 145 +/- 18 mmHg; patients without wearing-off, 138 +/- 17 mmHg), fell during the first hour (patients with wearing-off, 119 +/- 17 mmHg; patients without wearing-off, 126 +/- 18 mmHg), and then rose again toward the end of the observation period (patients with wearing-off, 136 +/- 15 mmHg; patients without wearing-off, 138 +/- 18 mmHg). This BP change was statistically significant only in PD patients with wearing-off (P < 0.001). In conclusion, BP seems to fluctuate with motor impairment in PD patients with wearing-off. This fluctuation may represent autonomic dysfunction caused by the PD process itself, the effect of PD medication, or both.
Related Concept Videos
Parkinson's Disease: Treatment
Parkinson's Disease is primarily a result of the loss of dopaminergic neurons in the substantia nigra pars compacta. The cornerstone of its...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Parkinson's Disease: Overview
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Parkinson Disease l: Introduction