Identification and correction of guide wire malposition during internal jugular cannulation with ultrasound
1Division of Emergency Medicine, University of Medicine and Dentistry of New Jersey, Newark, New Jersey 07103, USA. drmikestone@gmail.com
Abstract:
Real-time ultrasound guidance for central venous catheterization increases success and reduces procedural complications. I describe a case in which guide wire resistance was encountered and real-time ultrasound visualization of the guide wire facilitated correction of guide wire malposition. No additional passes of the introducer needle were necessary and the chances of inadvertent carotid artery puncture or pneumothorax were therefore reduced. The technique described here may prove valuable when guide wire resistance is encountered while placing a central venous catheter.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Cardiac Catheterization IV: Nursing Management
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...