Related Experiment Video
Updated: Jul 16, 2026

Development of a Novel Internal Fixation Model for Rat Radial Fractures: Fracture Healing Assessment and Dorsal Root Ganglion Isolation
Published on: March 13, 2026
Surgical treatment of unstable distal radius fractures with volar locking plates
Kenichi Murakami1, Yoshihiro Abe, Kazuhisa Takahashi
1Department of Orthopaedic Surgery, Graduate School of Medicine, Chiba University, Chiba, Japan.
Background:
Surgical treatment of unstable distal radius fractures does not always yield a satisfactory outcome. The several surgical strategies available have problems associated with them. This study was undertaken to determine if volar locking plate fixation could be useful for treating unstable distal radius fractures.
Methods:
This retrospective follow-up study assessed 24 fractures in 24 patients with unstable distal radius fractures surgically treated with one of three volar locking plate systems. According to the AO classification system, 7 patients had type A3 fractures, 5 patients had type C2 fractures, and the remaining 12 patients had type C3 fractures. Radiographic measurements included volar tilt, radial inclination, and ulnar variance. Clinical outcomes were evaluated by active range of motion of the wrist and forearm, grip strength, Saito's wrist score, and the Japanese Society for Surgery of the Hand version of the Disabilities of the Arm, Shoulder, and Hand questionnaire (JSSH version of the DASH).
Results:
At the time of final follow-up (5 months minimum) the mean volar tilt was 8.1 degrees , radial inclination was 20 degrees, and ulnar variance was 0.4 mm. Mean wrist extension measured 61 degrees, wrist flexion 55 degrees, radial deviation 23 degrees, ulnar deviation 35 degrees, pronation 87 degrees, and supination 87 degrees. Grip strength recovered to a mean of 84% of the grip strength in the contralateral limb for patients who had injured their dominant hand and to a mean of 73% for patients who had injured their nondominant hand. Saito's wrist score calculations revealed 20 excellent and 4 good results. The mean DASH disability/symptom score was 9.9 points, and the mean DASH work module score was 8.2 points.
Conclusions:
The present study demonstrated that unstable distal radius fractures could be successfully treated with volar locking plate systems.
More Related Videos
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Flail Chest-II
Assessment:
1. Clinical Evaluation:
History: