Automatic detection of left ventricular ejection time from a finger photoplethysmographic pulse oximetry waveform:
Gregory S H Chan1, Paul M Middleton, Branko G Celler
1Biomedical Systems Laboratory, School of Electrical Engineering and Telecommunications, University of New South Wales, Sydney, NSW, 2052, Australia.
Abstract:
Left ventricular ejection time (LVET) is a useful measure of ventricular performance and preload. The present study explores a novel method of continuous LVET monitoring using a noninvasive finger photoplethysmographic pulse oximetry waveform (PPG-POW). A method for the automatic beat-to-beat detection of LVET from the finger PPG-POW is presented based on a combination of derivative analysis, waveform averaging and rule-based logic. The performance of the detection method was evaluated on 13 healthy subjects during graded head-up tilt. Overall, the correlation between the PPG-POW derived LVET and the aortic flow derived LVET was high and significant (r = 0.897, p < 0.05). The bias was -14 +/- 14 ms (mean +/- SD), and the percentage error was 9.7%. Although these results would not be sufficient to satisfy the requirement for clinical evaluation of LVET when absolute accuracy was demanded, the strong correlation between the PPG-POW LVET and the aortic LVET on an intra-subject basis (r = 0.945 +/- 0.043, mean +/- SD) would support the application of PPG-POW to detect the directional change in LVET of an individual. This could be very useful for the early identification of progressive hypovolaemia or blood loss. The present study has demonstrated a promising approach to extract potentially useful information from a noninvasive, easy-to-obtain signal that could be readily acquired either from existing patient monitoring equipment or from inexpensive instrumentation. More extensive investigation is necessary to evaluate the applicability of the present approach in clinical care monitoring.
More Related Videos
04:48Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical indicator...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...