Related Experiment Video
Updated: Jul 15, 2026

Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Contrast-enhanced hepatic magnetic resonance angiography at 3 T: does parallel imaging improve image quality?
Lisa M Ho1, Elmar M Merkle, Erik K Paulson
1Department of Radiology, Duke University Medical Center, Durham, NC 27710, USA. lisa.ho@duke.edu
Purpose:
To evaluate whether hepatic magnetic resonance angiography (MRA) performed at 3 T and acquired with a parallel imaging acceleration factor of 2 provides satisfactory image quality and adequate contrast-to-noise, compared with an acquisition without parallel imaging.
Materials And Methods:
Ten volunteers underwent both a standard (A) and an experimental (B) MRA protocol. Both protocols used a gadoteridol dose of 20 mL injected at 2 mL/s in a 3-T magnetic resonance (MR) system. Protocol B was identical to protocol A, except protocol B was performed with a parallel imaging acceleration factor of 2. Contrast-to-noise ratios (CNRs) were calculated in the suprarenal abdominal aorta, the common hepatic artery, and the right and left hepatic arteries. The same 4 vessels were rated for quality of arterial visualization using a 5-point scale (1 = poor to 5 = excellent). The paired t test and Wilcoxon rank sum test were used for statistical analysis.
Results:
The CNRs and qualitative scores were higher in all 4 vessels using protocol B. Mean CNRs in the suprarenal abdominal aorta, common hepatic artery, and the right and left hepatic arteries were 31, 33, 28, and 22 for protocol A and 36, 40, 36, and 25 for protocol B, respectively (P < 0.05 except the left hepatic arteries [P = 0.35]). Mean qualitative scores of the same vessels were 4.3, 3.7, 3.1, and 2.9 using protocol A and 4.4, 3.8, 3.5, and 3.2 for protocol B, respectively (P > 0.44).
Conclusions:
Parallel imaging performed in a 3-T MR system improves hepatic MRA both quantitatively and qualitatively.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT