Related Experiment Video
Updated: Jul 15, 2026

Fundamental Technical Elements of Freeze-fracture/Freeze-etch in Biological Electron Microscopy
Published on: September 11, 2014
Improved antigen retrieval in freeze-fracture cytochemistry by evaporation of carbon as first replication layer
Wiebke Schlörmann1, Markus John, Frank Steiniger
1Elektronenmikroskopisches Zentrum, Klinikum der Friedrich-Schiller-Universität, Ziegelmühlenweg 1, D-07743, Jena, Germany.
Abstract:
The recently developed freeze-fracture replica immunolabeling technique uses sodium dodecyl sulfate to clean replicas obtained from chemically unfixed, rapidly frozen cells by evaporation of platinum as first and carbon as second replication layer. The detergent dissolves remains of cellular material with the exception of components which are in direct contact to the replica film. Membrane lipids and membrane protein complexes of the protoplasmic and the exoplasmic membrane halves remain attached to the replica film and are accessible for cytochemical localization. We immunolabeled the membrane proteins caveolin-1 and connexin 43 in mouse cell lines as well as the membrane attached protein tetrachloroethene reductive dehalogenase (PceA) in bacterial cells at freeze-fracture replicas generated by different evaporation parameters. The labeling experiments for caveolin-1 and the PceA showed that freeze-fracture replication of cellular membranes accomplished with thin platinum layers as well as replication with carbon as first evaporation layer lead in these cases to an improved antigen retrieval, whereas the labeling efficiency of connexin 43 was not affected by different evaporation conditions.
More Related Videos
13:35Plunge Freezing: A Tool for the Ultrastructural and Immunolocalization Studies of Suspension Cells in Transmission Electron Microscopy
Published on: May 5, 2017
09:49Combined Optogenetic and Freeze-fracture Replica Immunolabeling to Examine Input-specific Arrangement of Glutamate Receptors in the Mouse Amygdala
Published on: April 15, 2016
Related Concept Videos
Preparation of Samples for Electron Microscopy
Cryo-electron Microscopy
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...