How accurate is Whiteside's line as a reference axis in total knee arthroplasty?
Fiona R Middleton1, Simon H Palmer
1St Peter's Hospital, Guildford Road, Chertsey, UK. fionamiddleton@doctors.org.uk
The Knee
|April 13, 2007
Summary
Whiteside's line is often used for rotational alignment in knee replacement surgery. However, this study found significant variations, suggesting it should not be the sole guide for accurate prosthesis positioning.
Area of Science:
- Orthopedic Surgery
- Biomechanical Engineering
- Anatomy
Background:
- Computer-assisted surgery enhances precision in knee prosthesis insertion.
- Accurate rotational alignment of the femoral prosthesis is crucial for optimal outcomes in total knee arthroplasty.
- Traditional and computer-assisted techniques rely on precise identification of bony morphology for prosthesis orientation.
Purpose of the Study:
- To evaluate the reliability and reproducibility of Whiteside's line as a rotational reference axis.
- To assess the accuracy of Whiteside's line in relation to the epicondylar axis in cadaveric distal femora.
- To determine if Whiteside's line alone is sufficient for guiding femoral prosthesis rotation.
Main Methods:
- A cadaveric study involving 50 distal femora.
- Measurement of the angle between Whiteside's line and the epicondylar axis.
- Statistical analysis of the measured angles to assess reliability and variation.
Main Results:
- Whiteside's line was found to be perpendicular to the epicondylar axis in most specimens (mean 91 degrees).
- Significant variation was observed, with angles ranging from 80 to 102 degrees.
- The standard deviation of 4.7 degrees indicates considerable variability in the measurements.
Conclusions:
- Whiteside's line exhibits variability and should not be used as the sole reference for rotational alignment in total knee arthroplasty.
- Multiple rotational assessment axes are recommended to minimize errors in femoral prosthesis positioning.
- Ensuring accurate rotational alignment is critical for patellar tracking, joint forces, and overall surgical success.