Rapid determination of cyclamate in foods by solid-phase extraction and capillary electrophoresis
Masao Horie1, Fusako Ishikawa, Mitsuo Oishi
1Department of Food Safety, Tokyo Metropolitan Institute of Public Health, 3-24-1 Hyakunin-cho, Shinjuku-ku, Tokyo 169-0073, Japan. Masao_Horie@member.metro.tokyo.jp
Abstract:
A method for the determination of cyclamate in food was developed using solid-phase extraction (SPE) and capillary electrophoresis (CE) with indirect ultraviolet (UV) detection. A 5-10 g sample in 0.1 mol/L hydrochloric acid was homogenized and made up to a volume of 50 mL with 0.1 mol/L hydrochloric acid. After the sample was centrifuged, 25 mL of supernatant was loaded into an Oasis HLB SPE cartridge. The cartridge was washed with 2 mL of demineralized water followed by 2 mL of 50% aqueous methanol, and cyclamate was eluted with 4.5 mL of 50% aqueous methanol. The eluate was added to a solution of sodium propionate (internal standard) for CE analysis. The cyclamate in the eluate was electrophoresed on a fused-silica capillary using 1 mmol/L hexadecyltrimethylammonium bromide and 10 mmol/L potassium sorbate as a running buffer. Detection and reference wavelengths of cyclamate determined with a UV detector were 300 and 254 nm, respectively. The calibration curves for cyclamate showed good linearity in the range of 2-1000 microg/mL and the limits of detection in beverage, fruit in syrup, jam, pickles and confectionary are sample dependent and ranged from 5-10 microg/g. The recovery of cyclamate added at a level of 200 microg/g to various kinds of foods was 93.3-108.3% and the relative standard deviation was less than 4.9% (n=3). A number of commercial samples were analyzed using the proposed method. Cyclamate was detected in one waume, two pickles, and two sunflower seeds. The quantitative values determined with CE correlated to those from high-performance liquid chromatography (HPLC) (the detected values of cyclamate in a sunflower seed measured by CE and HPLC were 3.40 g/kg and 3.51 g/kg, respectively). This analytical method for cyclamate using CE is especially suitable for use in the field.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:13Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...