Related Experiment Video
Updated: Jul 15, 2026

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Quantification of beta+ activity generated by hard photons by means of PET
D Möckel1, H Müller, J Pawelke
1Forschungszentrum Dresden-Rossendorf, Institute of Radiation Physics, PF 510119, 01314 Dresden, Germany. d.moeckel@fzd.de
Abstract:
Positron emission tomography (PET) as a method for quality assurance in radiotherapy is well investigated in the case of therapy with carbon ion beams and successfully applied at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany. By measuring the beta(+) activity distribution during the irradiation (in-beam PET), valuable information on the precision of the dose deposition can be obtained. To extend this efficient technique to other radiation treatment modalities may be worthwhile. For example, since positron emitters are generated by high-energy photons with energies above 20 MeV due to (gamma, n) reactions (predominantly (11)C and (15)O in tissue), in-beam PET seems to be feasible for radiation therapy with high-energy photons as also shown in Geant4 simulations. Quantitative results on the activation of tissue-equivalent materials at hard photon beams were obtained by performing off-beam PET experiments. Homogeneous PMMA phantoms as well as inhomogeneous phantoms were irradiated with high-energy bremsstrahlung. After the irradiation the distributions of the generated positron emitters in the phantoms were measured using a conventional PET scanner. Furthermore, the depth-dose distributions were determined by means of optically stimulated luminescence detectors. In the experiments an activity per dose comparable to that produced in a typical patient irradiation with carbon ions could be achieved for 34 MV bremsstrahlung. In addition, a high contrast in the PET images for materials with different density and stoichiometry could be detected. Thus, further research concerning the development of in-beam PET seems to be worthwhile.
More Related Videos
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Biological Effects of Radiation
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Types of Radioactivity