Related Experiment Video
Updated: Jul 15, 2026

10:52
Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
The use of bioabsorbable seamguard during laparoscopic appendectomy
Jeff G Tucker1, James Clay Copher, James P Reilly
1Department of Surgery, Northside Forsyth Hospital, Cumming, GA 30041, USA. docjtuck@bellsouth.net
Surgical Laparoscopy, Endoscopy & Percutaneous Techniques
|April 24, 2007
Summary
This study shows that using bioabsorbable seamguard during laparoscopic appendectomy significantly reduces staple line bleeding. This adjunct ensures complete hemostasis, improving safety for patients undergoing appendicitis treatment.
Area of Science:
- Surgical Innovation
- Gastrointestinal Surgery
- Minimally Invasive Procedures
Background:
- Laparoscopic appendectomy is a preferred surgical method for acute appendicitis.
- Endoscopic stapling for mesoappendix division can lead to common staple line bleeding, sometimes requiring intervention.
- Achieving complete hemostasis is crucial for preventing complications.
Purpose of the Study:
- To evaluate the efficacy and safety of bioabsorbable seamguard as an adjunct to endoscopic stapling.
- To determine if seamguard prevents intraoperative and postoperative bleeding after mesoappendiceal stapling.
- To assess the impact on complication rates in laparoscopic appendectomy.
Main Methods:
- A prospective study involving 33 adult patients undergoing laparoscopic appendectomy for acute appendicitis.
- Bioabsorbable seamguard was applied as an adjunct to endoscopic stapling of the mesoappendix.
- Surgeons assessed immediate staple line hemostasis and monitored for intraoperative and postoperative complications.
Main Results:
- Complete immediate staple line hemostasis was achieved in all 33 cases.
- No intraoperative complications were reported.
- No late infectious intra-abdominal or postoperative bleeding complications occurred.
Conclusions:
- Bioabsorbable seamguard is a safe and effective adjunct for endoscopic mesoappendiceal stapling.
- The use of seamguard successfully prevents both intraoperative and postoperative staple line bleeding.
- This adjunct enhances the safety profile of laparoscopic appendectomy for acute appendicitis.