Pulmonary nodules: sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT
Philipp Peloschek1, Johannes Sailer, Michael Weber
1Department of Radiology, Vienna Medical University, Währinger Gürtel 18-20, A-1090 Vienna, Austria; Department of Radiology, Utrecht Medical Center, Utrecht, the Netherlands.
Purpose:
To prospectively compare maximum intensity projection (MIP) and volume rendering (VR) of multidetector computed tomographic (CT) data for the detection of small intrapulmonary nodules.
Materials And Methods:
This institutional review board-approved prospective study included 20 oncology patients (eight women and 12 men; mean age, 56 years +/- 16 [standard deviation]) who underwent clinically indicated standard-dose thoracic multidetector CT and provided informed consent. Transverse thin slabs of the chest (thickness, 7 mm; reconstruction increment, 3.5 mm) were created by using MIP and VR techniques to reconstruct CT data (collimation, 16 x 0.75 mm) and were reviewed in interactive cine mode. Mean, minimum, and maximum reading time per examination and per radiologist was documented. Three radiologists digitally annotated all nodules seen in a way that clearly determined their locations. The maximum number of nodules detected by the three observers and confirmed by consensus served as the reference standard. Descriptive statistics were calculated, with P < .05 indicating a significant difference. The Wilcoxon matched-pairs signed rank test and confidence intervals for differences between methods were used to compare the sensitivities of the two methods.
Results:
VR performed significantly better than MIP with regard to both detection rate (P < .001) and reporting time (P < .001). The superiority of VR was significant for all three observers and for nodules smaller than 11 mm in diameter and was pronounced for perihilar nodules (P = .023). Sensitivities achieved with VR ranged from 76.5% to 97.3%, depending on nodule size.
Conclusion:
VR is the superior reading method compared with MIP for the detection of small solid intrapulmonary nodules.