Related Experiment Video
Updated: Jul 15, 2026

3D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
Published on: September 19, 2025
Patient motion correction for multiplanar, multi-breath-hold cardiac cine MR imaging
Piotr J Slomka1, David Fieno, Amit Ramesh
1Department of Imaging, Cedars-Sinai Medical Center, #A047 8700 Beverly Boulevard, Los Angeles, CA 90048, USA. Piotr.Slomka@cshs.org
Purpose:
To correct for spatial misregistration of multi-breath-hold short-axis (SA), two-chamber (2CH), and four-chamber (4CH) cine cardiac MR (CMR) images caused by respiratory and patient motion.
Materials And Methods:
Twenty CMR studies from consecutive patients with separate breath-hold 2CH, 4CH, and SA 20-phase cine images were considered. We automatically registered the 2CH, 4CH, and SA images in three dimensions by minimizing the cost function derived from plane intersections for all cine phases. The automatic alignment was compared with manual alignment by two observers.
Results:
The processing time for the proposed method was <20 seconds, compared to 14-24 minutes for the manual correction. The initial plane displacement identified by the observers was 2.8 +/- 1.8 mm (maximum = 14 mm). A displacement of >/=5 mm was identified in 15 of 20 studies. The registration accuracy (defined as the difference between the automatic parameters and those obtained by visual registration) was 1.0 +/- 0.9 mm, 1.1 +/- 1.0 mm, 1.1 +/- 1.2 mm, and 2.0 +/- 1.8 mm for 2CH-4CH alignment and SA alignment in the mid, basal, and apical regions, respectively. The algorithm variability was higher in the apex (2.0 +/- 1.9 mm) than in the mid (1.4 +/- 1.4 mm) or basal (1.2 +/- 1.2 mm) regions (ANOVA, P < 0.05).
Conclusion:
An automated preprocessing algorithm can reduce spatial misregistration between multiple CMR images acquired at different breath-holds and plane orientations.
More Related Videos
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...