Visualization of Intensity Levels to Reduce the Gap Between Self-Reported and Directly Measured Physical Activity
Published on: March 7, 2019
Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity
Søren Brage1, Ulf Ekelund, Niels Brage
1MRC Epidemiology Unit, Cambridge CB1 9NL, UK. soren.brage@mrc-epid.cam.ac.uk
Abstract:
Combining accelerometry with heart rate (HR) monitoring may improve precision of physical activity measurement. Considerable variation exists in the relationships between physical activity intensity (PAI) and HR and accelerometry, which may be reduced by individual calibration. However, individual calibration limits feasibility of these techniques in population studies, and less burdensome, yet valid, methods of calibration are required. We aimed to evaluate the precision of different individual calibration procedures against a reference calibration procedure: a ramped treadmill walking-running test with continuous measurement of PAI by indirect calorimetry in 26 women and 25 men [mean (SD): 35 (9) yr, 1.69 (0.10) m, 70 (14) kg]. Acceleration (along the longitudinal axis of the trunk) and HR were measured simultaneously. Alternative calibration procedures included treadmill testing without calorimetry, submaximal step and walk tests with and without calorimetry, and nonexercise calibration using sleeping HR and gender. Reference accelerometry and HR models explained >95% of the between-individual variance in PAI (P < 0.001). This fraction dropped to 73 and 81%, respectively, for accelerometry and HR models calibrated with treadmill tests without calorimetry. Step-test calibration captured 62-64% (accelerometry) and 68% (HR) of the variance between individuals. Corresponding values were 63-76% and 59-61% for walk-test calibration. There was only little benefit of including calorimetry during step and walk calibration for HR models. Nonexercise calibration procedures explained 54% (accelerometry) and 30% (HR) of the between-individual variance. In conclusion, a substantial proportion of the between-individual variance in relationships between PAI, accelerometry, and HR is captured with simple calibration procedures, feasible for use in epidemiological studies.
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Measuring Acceleration Due to Gravity
A simple pendulum can be described as a point mass and a string. Meanwhile, a physical pendulum is any object whose oscillations are similar to a simple pendulum, but cannot be modeled as a point mass on a string because its mass is distributed over a larger area. The behavior of a physical pendulum can be modeled using the principles of...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Measurement of Blood Pressure
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated. For...