Purpose:
Immediate surgical repair and early mobilization are essential in preventing adhesion formation and finger stiffness. A new polyethylene-based, braided suture material, Fiberwire (Arthrex, Naples, FL), touting increased strength, presents the potential for stronger repairs and, therefore, earlier active motion after surgery with a greater safety margin. The purpose of this biomechanic study was to investigate the differences in gap formation, tensile strength, and mode of failure for 2 distinct repair techniques using nylon, Ethibond (Ethicon, Somerville, NJ), and Fiberwire.
Methods:
Human cadaver flexor tendons were harvested and repaired in a randomized fashion with either the Strickland or Massachusetts General Hospital (MGH) repairs using either nylon, Ethibond, or Fiberwire. Twelve tendons per group were repaired for each combination of material and method. During load-to-failure testing, 2-mm gap force and maximum tensile strength were statistically analyzed.
Results:
Strickland repairs failed by suture pull-out in 74% of repairs, whereas 99% of the MGH repairs failed by suture breakage. For MGH repairs, Fiberwire suture provided significantly more tensile strength than Ethibond and nylon. For Strickland repairs, where the mode of failure was more often by suture pull-out rather than breakage, differences between type of suture were not significant. When comparing repair techniques using Fiberwire, the MGH repair was significantly stronger than the Strickland repair.
Conclusions:
Biomechanic testing shows that Fiberwire outperforms both Ethibond and nylon suture when using a locked flexor tendon repair suture (MGH repair) but not when using a grasping-type, nonlocking repair (Strickland repair).
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Clot Retraction and Fibrinolysis
Structural Joints: Fibrous Joints
Suture
All the bones of the skull, except for the mandible, are joined to each other by a fibrous joint called a suture. The fibrous connective tissue found at a suture strongly unites the adjacent skull bones and thus helps to protect the brain and form the face. In...
Phases of Wound Repair
Formation of Blood Clot
In case of deep injuries, trauma to blood vessels results in blood loss. In the meantime, phospholipids released from the ruptured endothelial cellular membrane are converted into arachidonic...