NaviStar ThermoCool catheter for ventricular tachycardia
1QEII Health Sciences Centre, Department of Medicine, Cardiology Division, 1796 Summer Street, Room 2501, Halifax, Nova Scotia, B3H 3A7, Canada. amir.abdelwahab@cdha.nshealth.ca
Catheter ablation effectively treats cardiac arrhythmias using advanced technologies like irrigated radiofrequency ablation and 3D mapping. The Navistar ThermoCool catheter offers an integrated approach for ventricular tachycardia ablation.
Area of Science:
- Cardiology
- Electrophysiology
- Medical Device Technology
Background:
- Catheter ablation is a successful treatment for cardiac arrhythmias.
- Technological advancements have significantly improved electrophysiology practices.
- Irrigated radiofrequency ablation and 3D mapping enhance treatment of complex arrhythmias like atrial fibrillation and ventricular tachycardia.
Purpose of the Study:
- To discuss the design, clinical profile, advantages, and complications of the Navistar ThermoCool ablation catheter.
- To highlight the role of integrated electroanatomical guidance and irrigated tip technology in ventricular tachycardia ablation.
Main Methods:
- Review of the Navistar ThermoCool ablation catheter, approved in 2006 for ventricular tachycardia ablation.
- Discussion of irrigated tip design and electroanatomical guidance integration.
Main Results:
- The Navistar ThermoCool catheter combines irrigated ablation with electroanatomical guidance.
- This technology facilitates the treatment of complex arrhythmias, specifically ventricular tachycardia.
Conclusions:
- The Navistar ThermoCool catheter represents a significant technological advancement in ventricular tachycardia ablation.
- Integrated irrigated tip design and electroanatomical guidance contribute to improved efficacy and safety in treating ventricular tachycardia.
More Related Videos
09:47A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
Published on: April 26, 2015
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
Related Concept Videos
Cardiac Catheterization IV: Nursing Management
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Cardiac Catheterization I: Pre-Procedure Overview
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...