Elimination of matrix effect and simultaneous determination of multi-components in complex systems by matrix
Tai-Ming Zhang1, Bin Yuan, Yi-Zeng Liang
1College of Chemistry and Chemical Engineering, Central South University, China.
Abstract:
In order to deal with the matrix effect in the simultaneous determination of multi-components in a complex system, we have developed a novel method named matrix coefficient multivariate calibration method (MCMCM) for simultaneously determining n analytes in complex systems. The calibration models of n analytes, which are based on the experimental data of known samples, are first transformed into n linear equations, and then the equations are solved to obtain matrix calibration coefficients of the analytes in congeneric samples. In this way, the concentrations of n analytes in the unknown sample could be obtained easily and simultaneously by solving another n-variate linear equations with the help of the matrix calibration coefficients obtained-above. The method proposed in this work has been tested by voltammetry and atomic absorption spectrometry (AAS) with satisfactory results. On determining the elements such as Cu, Pb, Cd, Ni, Zn, Fe, Mn, Co, Ca, Mg, etc. in synthetic samples, the relative standard deviations (RSDs) of the results were 0.91 - 4.5%, and the recoveries were 95.8 - 105%. For actual samples, the RSDs and the recoveries were 1.5 - 6.9 and 92.0 - 110%, respectively.
Related Concept Videos
Multi-input and Multi-variable systems
In the absence of...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Gaussian Elimination: Problem Solving
Classification of Systems-I
Homogeneity dictates that if an input x(t) is multiplied by a constant c, the output y(t) is multiplied by the same constant. Mathematically, this is expressed as:
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...


