Multiresponse optimization and parallel factor analysis, useful tools in the determination of estrogens by gas
David Arroyo1, M Cruz Ortiz, Luis A Sarabia
1Department of Chemistry, Faculty of Sciences, University of Burgos, Pza. Misael Bañuelos s/n, 09001 Burgos, Spain.
Abstract:
This paper reports an experimental design optimization of a recently proposed silylation procedure that avoids the introduction of false positives and false negatives in the simultaneous determination of steroid hormone estrone (E1) and 17-alpha-ethinylestradiol (EE2) by gas chromatography-mass spectrometry (GC/MS). The figures of merit for several calibration procedures were evaluated under optimum conditions in the silylation step. Internal standardization strategies were applied and global models were constructed by gathering signals recorded on three non-consecutive days. Three calibration models were examined: a univariate model with a sum of six monitorized ions and a three-way PARAFAC-based model (the analyte scores were standardized on the basis of the scores of the internal standard). The global PARAFAC-based calibration model showed the best performance with detection capabilities of 4.3 microg l(-1) and 7.0 microg l(-1) for E1 and EE2, respectively, when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1 and for EE2 was 11.1% and 8.5%, respectively, and trueness was likewise confirmed. The proposed optimized derivatization procedure using a three-way calibration function was also applied in the determination of E1, 17-beta-estradiol (E2) and EE2 in bovine urine samples: recovery values were 68.5%, 40.4% and 43.4%, respectively, and the detection capability was 18.4, 19.3 and 18.6 microg l(-1) when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1, E2 and EE2 was 7.4%, 9.4% and 8.6%, respectively, and trueness was likewise confirmed.
More Related Videos
09:49Use of a Battery of Chemical and Ecotoxicological Methods for the Assessment of the Efficacy of Wastewater Treatment Processes to Remove Estrogenic Potency
Published on: September 11, 2016
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Methods of Medium Optimization
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.