Related Experiment Video
Updated: Jul 14, 2026

In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy
Published on: December 9, 2015
Transsplenic portal scintigraphy using 99mTc-mebrofenin in normal dogs
Federica Morandi1, Robert C Cole, Rita L Echandi
1Department of Small Animal Clinical Sciences, University of Tennessee College of Veterinary Medicine, Knoxville, USA. fmorandi@utk.edu
Abstract:
Transsplenic portal scintigraphy using sodium pertechnetate is superior to per-rectal portal scintigraphy due to improved visualization of the portal vasculature with decreased patient and personnel exposure. The purpose of this study was to describe the use of 99mTc-mebrofenin, the radiopharmaceutical of choice for the evaluation of hepatic function, in place of pertechnetate for transsplenic portal scintigraphy in normal dogs. Sixteen juvenile dogs underwent transsplenic portal scintigraphy using 37-130 MBq 99mTc-mebrofenin in a 0.2-0.5 ml volume. After the initial dynamic acquisition obtained at 4 frames/s in right lateral recumbency, static right lateral, and ventral views were obtained at 5, 10, 15, 20, 25, 30, 40, 50, and 60 min. A nuclear angiogram of the splenic and portal veins was visible in all dogs, followed by rapid distribution of the radiopharmaceutical in the liver. Hepatic morphology was more easily defined than with pertechnetate. Transit time could not be calculated due to the high hepatic extraction of 99mTc-mebrofenin. Mean +/- SD shunt fraction was 0.8 +/- 0.8%. Time to peak liver activity was 3.1 +/- 1.1 min, and hepatic excretion T1/2 was 19.4 +/- 6.3 min. No visible blood pool and cardiac activity was seen after 5 min. The mean +/- SD time to visualization of defined biliary activity was 8.8 +/- 2.9 min. Absorption from the spleen was significantly higher than that reported for pertechnetate (87.9 +/- 8.2%, vs. 52.5 +/- 19.1%). 99mTc-mebrofenin can be used in place of pertechnetate for transsplenic portal scintigraphy, with the advantage of combining quantitative parameters of liver function with the already known advantage of transsplenic portal scintigraphy.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

