Related Experiment Video
Updated: Jul 14, 2026

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Validation of remote cardiopulmonary examination in patients with heart failure with a videophone-based system
Gabriele Fragasso1, Amarild Cuko, Roberto Spoladore
1Clinical Cardiology-Heart Failure Unit, Istituto Scientifico San Raffaele, Milano, Italy.
Background:
The aim of this study was to evaluate feasibility and accuracy of a videophone-based system for remote cardiopulmonary examination of patients with heart failure.
Methods And Results:
Fifty patients were examined by 2 cardiologists, 1 with a conventional stethoscope and 1 remotely with a videophone-based method, employing an electronic stethoscope and transmitting through an integrated services digital network line. During both sessions, the cardiologists filled out a 27-item questionnaire, which was then compared; concordance between standard and remote examination was evaluated. In 92% of patients, electronic and acoustic auscultation concurred. Only in 3 patients (4%) did teleauscultation not permit a correct interpretation of lung examination. In one patient, bilateral fine crepitant rales were not detected during teleauscultation. Conversely, in the second, patient bilateral fine crepitant rales were recognized during teleauscultation, which were not confirmed during real-life auscultation. In the third nonconcordant patient, moderate-degree wheezing was not detected during teleauscultation. Fine crepitant rales were present at the lungs lower fields in 12 and wheezing in 3 additional patients, and were always correctly identified during teleauscultation. Overall, sensitivity, specificity, positive, and negative predictive value of remote lung auscultation were 88%, 97%, 94%, and 94%, respectively.
Conclusions:
Remote cardiopulmonary examination appears as a feasible method for assessing patients with heart failure. Telestethoscopy can therefore be reliably used in the context of comprehensive telecare programs.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...