Related Experiment Video
Updated: Jul 14, 2026

Breath Collection from Children for Disease Biomarker Discovery
Published on: February 14, 2019
Prediction of lung cancer using volatile biomarkers in breath
Michael Phillips1, Nasser Altorki, John H M Austin
1Menssana Research Inc, Fort Lee, NJ 07024-6510, USA. mphillips@menssanaresearch.com
Background:
Normal metabolism generates several volatile organic compounds (VOCs) that are excreted in the breath (e.g. alkanes). In patients with lung cancer, induction of high-risk cytochrome p450 genotypes may accelerate catabolism of these VOCs, so that their altered abundance in breath may provide biomarkers of lung cancer.
Methods:
VOCs in 1.0 L alveolar breath were analyzed in 193 subjects with primary lung cancer and 211 controls with a negative chest CT. Subjects were randomly assigned to a training set or to a prediction set in a 2:1 split. A fuzzy logic model of breath biomarkers of lung cancer was constructed in the training set and then tested in subjects in the prediction set by generating their typicality scores for lung cancer.
Results:
Mean typicality scores employing a 16 VOC model were significantly higher in lung cancer patients than in the control group (p<0.0001 in all TNM stages). The model predicted primary lung cancer with 84.6% sensitivity, 80.0% specificity, and 0.88 area under curve (AUC) of the receiver operating characteristic (ROC) curve. Predictive accuracy was similar in TNM stages 1 through 4, and was not affected by current or former tobacco smoking. The predictive model achieved near-maximal performance with six breath VOCs, and was progressively degraded by random classifiers. Predictions with fuzzy logic were consistently superior to multilinear analysis. If applied to a population with 2% prevalence of lung cancer, a screening breath test would have a negative predictive value of 0.985 and a positive predictive value of 0.163 (true positive rate =0.277, false positive rate =0.029).
Conclusions:
A two-minute breath test predicted lung cancer with accuracy comparable to screening CT of chest. The accuracy of the test was not affected by TNM stage of disease or tobacco smoking. Alterations in breath VOCs in lung cancer were consistent with a non-linear pathophysiologic process, such as an off-on switch controlling high-risk cytochrome p450 activity. Further research is needed to determine if detection of lung cancer with this test will reduce mortality.
More Related Videos
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
Related Concept Videos
Serum Laboratory Studies, Stool Test, Breath Test
Statistical Methods for Analyzing Epidemiological Data