Related Experiment Video
Updated: Jul 14, 2026

Recapitulation of an Ion Channel IV Curve Using Frequency Components
Published on: February 8, 2011
The effect of AM noise on correlation phase-noise measurements
Enrico Rubiola1, Rodolphe Boudot
1Franche-Comté Electronique, Mécanique, Thermique et Optique-Sciences et Technologies (FEMTO-ST) Institute, Unité Mixte de Recherche (UMR) 6174, CNRS and Université de Franche Comté, Besançon, France. rubiola@femto.st.fr
Abstract:
We analyze the phase-noise measurement methods in which correlation and averaging is used to reject the background noise of the instrument. All the known methods make use of a mixer, used either as a saturated-phase detector or as a linear-synchronous detector. Unifortunately, AM noise is taken in through the power-to-dc-offset conversion mechanism that results from the mixer asymmetry. The measurement of some mixers indicates that the unwanted amplitude-to-voltage gain is of the order of 5-50 mV, which is 12-35 dB lower than the phase-to-voltage gain of the mixer. In addition, the trick of setting the mixer at a sweet point--off the quadrature condition--where the sensitivity to AM nulls, works only with microwave mixers. The HF-VHF mixers do not have this sweet point. Moreover, we prove that if the AM noise comes from the oscillator under test, it cannot be rejected by correlation. At least not with the schemes currently used. An example shows that at some critical frequencies the unwanted effect of AM noise is of the same order-if not greater--than the phase noise. Thus, experimental mistakes are around the corner.
Related Concept Videos
Correlation of Experimental Data
For example, a spherical particle moving through a viscous fluid experiences drag. Dimensional analysis shows that the drag force depends on the particle's diameter, velocity, and...
2D NMR: Overview of Heteronuclear Correlation Techniques
Calibration Curves: Correlation Coefficient
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any finite,...
2D NMR: Overview of Homonuclear Correlation Techniques
COSY90 is the standard two-dimensional (2D) COSY experiment that...

