Related Experiment Video
Updated: Feb 6, 2026

Author Spotlight: Unraveling the Impact of Mechanical Ventilation on Diaphragm Function and Patient Outcomes
Published on: November 3, 2023
Paradoxical low-flow, low-gradient severe aortic stenosis despite preserved ejection fraction is associated with
Zeineb Hachicha1, Jean G Dumesnil, Peter Bogaty
1Laval Hospital Research Center/Quebec Heart Institute, Department of Medicine, Laval University, Quebec, Canada.
Background:
Recent studies and current clinical observations suggest that some patients with severe aortic stenosis on the basis of aortic valve area may paradoxically have a relatively low gradient despite the presence of a preserved left ventricular (LV) ejection fraction. The objective of the present study was to document the prevalence, potential mechanisms, and clinical relevance of this phenomenon.
Methods And Results:
We retrospectively studied the clinical and Doppler echocardiographic data of 512 consecutive patients with severe aortic stenosis (indexed aortic valve area < or = 0.6 cm2 x m(-2)) and preserved LV ejection fraction (> or = 50%). Of these patients, 331 (65%) had normal LV flow output defined as a stroke volume index > 35 mL x m2, and 181 (35%) had paradoxically low-flow output defined as stroke volume index < or = 35 mL x m(-2). When compared with normal flow patients, low-flow patients had a higher prevalence of female gender (P<0.05), a lower transvalvular gradient (32+/-17 versus 40+/-15 mm Hg; P<0.001), a lower LV diastolic volume index (52+/-12 versus 59+/-13 mL x m(-2); P<0.001), lower LV ejection fraction (62+/-8% versus 68+/-7%; P<0.001), a higher level of LV global afterload reflected by a higher valvulo-arterial impedance (5.3+/-1.3 versus 4.1+/-0.7 mm Hg x mL(-1) x m(-2); P<0.001) and a lower overall 3-year survival (76% versus 86%; P=0.006). Only age (hazard ratio, 1.04; 95% CI, 1.01 to 1.08; P=0.025), valvulo-arterial impedance > 5.5 mm Hg x mL(-1) x m(-2) (hazard ratio, 2.6; 95% CI, 1.2 to 5.7; P=0.017), and medical treatment (hazard ratio, 3.3; 95% CI, 1.8 to 6.7; P=0.0003) were independently associated with increased mortality.
Conclusion:
Patients with severe aortic stenosis may have low transvalvular flow and low gradients despite normal LV ejection fraction. A comprehensive evaluation shows that this pattern is in fact consistent with a more advanced stage of the disease and has a poorer prognosis. Such findings are clinically relevant because this condition may often be misdiagnosed, which leads to a neglect and/or an underestimation of symptoms and an inappropriate delay of aortic valve replacement surgery.
More Related Videos
12:32High-resolution Respirometry to Measure Mitochondrial Function of Intact Beta Cells in the Presence of Natural Compounds
Published on: January 23, 2018
11:24Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
Published on: July 4, 2015
Related Concept Videos
05:51Measuring Diaphragm Thickness and Function Using Point-of-Care Ultrasound
08:47Oral Health Assessment by Lay Personnel for Older Adults
05:17Preparation of High-Quality Fermented Fish Product
12:32High-resolution Respirometry to Measure Mitochondrial Function of Intact Beta Cells in the Presence of Natural Compounds
11:24Measuring DNA Damage and Repair in Mouse Splenocytes After Chronic In Vivo Exposure to Very Low Doses of Beta- and Gamma-Radiation
04:57Proper Care and Cleaning of the Microscope