Related Experiment Video
Updated: Jul 14, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Examination of patient skin dose during abdominal interventional radiology using a GAF system]
Akitami Matsushita1, Toshizo Katsuda, Taketo Kawamura
1Department of Radiology, Okayama Kyokuto Hospital, Japan.
Abstract:
Radiation-induced skin injury caused by interventional radiology(IVR)is a deterministic effect. If exposure dose exceeds threshold dose, injuries may occur. It therefore is important to understand the maximum exposure dose in skin. The purpose of this study was to determine the maximum exposure dose and its dose distribution. Moreover, to analyze the factors from measuring the absorbed dose in the incoming radiation side, a film-type dosimeter was used. When the measured results were determined in terms of the clinical aspect, fluoroscopic time(total time)in procedure, it ranged from 3.3 to 64.0 minutes, and DSA images obtained ranged from 8 to 280 images. Absorbed dose ranged from 0.3 to 6.0 Gy, with an average dose of 3.2 Gy. It thus exceeded 2 or 3 Gy, which was the threshold dose of temporary erythematic or depilation in 10 of 14 cases. The maximum dose was 6.0 Gy for a procedure of percutaneous transhepatic obliteration. The maximum exposure dose can be determined objectively by using a film-type dosimeter. It was also possible to grasp the overall dose distribution visually.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
07:43In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Related Concept Videos
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies II: Ultrasonography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography