Related Experiment Video
Updated: Jul 14, 2026

Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Bymixer system can measure O2 uptake and CO2 elimination in the anesthesia circle circuit
Abraham Rosenbaum1, Christopher W Kirby, Peter H Breen
1Department of Anesthesiology, UCI Medical Center, Orange, CA 92868, USA.
Background:
The ability to measure carbon dioxide elimination (Vco(2)), oxygen uptake (Vo(2)), and R (respiratory exchange ratio, Vco(2)/Vo(2)) during anesthesia may help the non-invasive detection of critical events (e.g., abrupt decrease in cardiac output) and metabolic upset (e.g., onset of anaerobic metabolism).
Methods:
We have developed a new clinical bymixer (inline mixing chamber) that can measure mixed inspired and expired gas fractions in the anesthesia circle circuit. The addition of a standard anesthesia gas analyzer and flowmeter, and a new airway temperature and humidity sensor, allow determinations of Vco(2) and Vo(2) at the airway opening of the circle circuit. Over a range of tidal volume and frequency, Vco(2) and Vo(2) were compared to reference values generated by the combustion of metered liquid ethanol in a new metabolic lung simulator.
Results:
By linear regression, bymixer-flow measurements of Vco(2) (slope = 1.02, Y-intercept = -5.31, coefficient of determination, R(2) = 0.998) and Vo(2) (slope = 1.05, Y-intercept = -4.34, R(2) = 0.993) correlated closely to the reference values generated by the metabolic lung simulator. Limits of agreement analysis generated percent errors (mean +/- 1.96 SD) of -1.2 +/- 7.2% for Vco(2) and 2.5 +/- 9.8% for Vo(2).
Conclusions:
The new clinical bymixer is compact, lightweight, disposable, inexpensive, and has a fast and adjustable response time (time constant about 14 sec). Anesthesia circle circuit integrity is maintained. Bymixer-flow measurements of Vco(2) and Vo(2) are accurate and may add to clinical monitoring under anesthesia and surgery.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...