Cardiac Pressure-Volume Loop Analysis Using Conductance Catheters in Mice
Published on: September 17, 2015
Cardiac output derived from left ventricular pressure during conductance catheter evaluations: an extended Modelflow
Sergio Valsecchi1, Giovanni B Perego, Jan J Schreuder
1Medtronic Italia, Via Lucrezio Caro, Rome, Italy. sergio.valsecchi@medtronic.com
Objective:
The Modelflow method computes cardiac output (CO) from arterial pressure (CO-MFao) by simulating a non-linear three-element Windkessel model of aortic input impedance. We present a novel technique to apply the Modelflow method to the left ventricular pressure (Plv) signal, to obtain an estimation of CO (CO-MFlv).
Methods:
We extended the model by simulating the aortic valve as a resistance placed in series to the characteristic impedance. In our model the valve resistance is infinite in diastole, while it has a patient related value during systole. Twenty one patients with heart failure were studied with a combined pressure-conductance catheter positioned in the left ventricle and a micromanometer in the aorta. CO changes were induced during temporary sequential atrio-biventricular pacing with different atrio-ventricular and inter-ventricular intervals. After a single calibration we compared CO-MFlv with CO-MFao (516 measurement series) and with CO estimated by the conductance catheter volume technique (CO-cond) (267 series).
Results:
CO ranged from 2.42 to 7.59 l/min with an overall mean of 4.36 (1.38) l/min. Comparing the two Modelflow methods, the bias was -0.04 (0.36) l/min, with limits of agreement of -0.77 and 0.70 l/min, and a coefficient of variation of 8.4%. Of the 516 changes in CO from baseline values, 112 were greater than 0.5 l/min and 110 of these (98%) were scored in the same direction by both methods. For comparisons between CO-MFlv and CO-cond the bias was -0.10 (0.49), with limits of agreement of -1.12 and 0.90 l/min, and a coefficient of variation of 12.5%.
Conclusions:
Cardiac output estimates by the modelflow method from aortic pressure and left ventricular pressure are interchangeable in patients without mitral and aortic abnormalities. After an initial calibration, CO-MFlv presents near zero bias and an adequate precision.
More Related Videos
Related Concept Videos
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...