Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Nuclear Transmutation03:20

Nuclear Transmutation

Nuclear transmutation is the conversion of one nuclide into another. It can occur by the radioactive decay of a nucleus, or the reaction of a nucleus with another particle. The first manmade nucleus was produced in Ernest Rutherford’s laboratory in 1919 by a transmutation reaction, the bombardment of one type of nuclei with other nuclei or with neutrons. Rutherford bombarded nitrogen-14 atoms with high-speed α particles from a natural radioactive isotope of radium and observed protons being...
Subatomic Particles03:37

Subatomic Particles

Dalton was only partially correct about the particles that make up matter. All matter is composed of atoms, and atoms are composed of three smaller subatomic particles: protons, neutrons, and electrons. These three particles account for the mass and the charge of an atom.
Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...
Atomic Nuclei: Nuclear Magnetic Moment00:59

Atomic Nuclei: Nuclear Magnetic Moment

All atomic nuclei are positively charged. When they have a nonzero spin, they behave like rotating charges. As a consequence of their charge and spin, these nuclei generate a magnetic field (B). This, in turn, gives rise to a magnetic moment (μ), which is randomly oriented in the absence of an external magnetic field. When an external magnetic field (B0) is applied, the magnetic moment vectors can align with the field or against it in 2 + 1 orientations. A hydrogen nucleus, which is just a...
Electron Behavior01:09

Electron Behavior

Electrons are negatively charged subatomic particles attracted to and orbit around the positively-charged nucleus of an atom. They reside in spaces associated with energy levels called shells and are further organized into subshells and orbitals within each shell.
Electrons Orbit the Nucleus
Electrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the nucleus have less energy,...
Electron Behavior00:54

Electron Behavior

Electrons are negatively charged subatomic particles that are attracted to an orbit around the positively-charged nucleus of an atom. They reside in locations that are associated with energy levels called shells and are further organized into sub-shells and orbitals within each shell.Electrons Orbit the NucleusElectrons are found in specific locations outside of the nucleus. The shell in which an electron resides indicates the general energy level of the electron: those closer to the nucleus...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Recommendations for the use of active personal dosemeters (APDs) in interventional workplaces in hospitals.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2021
Same author

PATIENT-SPECIFIC DOSE ESTIMATES IN DYNAMIC COMPUTED TOMOGRAPHY MYOCARDIAL PERFUSION EXAMINATION.

Radiation protection dosimetry·2021
Same author

ESTIMATION OF HP(3) AMONG STAFF MEMBERS IN TWO NUCLEAR MEDICINE UNITS IN FINLAND.

Radiation protection dosimetry·2020
Same author

Calculated beam quality correction factors for ionization chambers in MV photon beams.

Physics in medicine and biology·2020
Same author

CT beam dosimetric characterization procedure for personalized dosimetry.

Physics in medicine and biology·2019
Same author

Establishing the European diagnostic reference levels for interventional cardiology.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2018

Related Experiment Video

Updated: Jul 14, 2026

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

Dose from slow negative muons.

T Siiskonen1

  • 1STUK-Radiation and Nuclear Safety Authority, PO Box 14, FIN-00881 Helsinki, Finland. teemu.siiskonen@stuk.fi

Radiation Protection Dosimetry
|June 5, 2007
PubMed
Summary

Accurate dose estimation for slow negative muons requires detailed energy spectra and decay yields, especially for high-LET particles. Using a radiation-weighting factor of unity for slow muons can significantly underestimate skin equivalent dose.

Area of Science:

  • Radiation Dosimetry
  • High-Energy Particle Physics
  • Health Physics

Background:

  • Slow negative muons, when stopped, decay into various particles including energetic photons, electrons, and high-Linear Energy Transfer (LET) particles.
  • Accurate estimation of dose equivalent is crucial for radiation protection.

Purpose of the Study:

  • To examine conversion coefficients from fluence to ambient dose equivalent and maximum dose equivalent for slow negative muons.
  • To calculate quality factors and the contribution of each secondary particle type to the dose equivalent.
  • To assess the conservativeness of ambient dose equivalent estimates for slow negative muons.

Main Methods:

  • Detailed examination of conversion coefficients.
  • Calculation of dose equivalent contributions from secondary particles (photons, electrons, high-LET particles).

More Related Videos

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Setting Limits on Supersymmetry Using Simplified Models
07:46

Setting Limits on Supersymmetry Using Simplified Models

Published on: November 15, 2013

Related Experiment Videos

Last Updated: Jul 14, 2026

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh
10:42

Preparing an Isotopically Pure 229Th Ion Beam for Studies of 229mTh

Published on: May 3, 2019

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
06:28

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera

Published on: January 30, 2020

Setting Limits on Supersymmetry Using Simplified Models
07:46

Setting Limits on Supersymmetry Using Simplified Models

Published on: November 15, 2013

  • Analysis of energy spectra and decay yields for high-LET particles.
  • Comparison with previous studies.
  • Main Results:

    • The energy spectra and decay yields of high-LET particles are critical for precise dose estimations.
    • Ambient dose equivalent may not consistently provide a conservative estimate for protection quantities for slow negative muons.
    • Using a radiation-weighting factor of unity for slow muons leads to a significant underestimation of the skin equivalent dose.

    Conclusions:

    • Detailed spectral information is essential for accurate dosimetry of slow negative muons.
    • Current protection quantity estimations may be inadequate for slow negative muons, particularly concerning skin dose.
    • Re-evaluation of radiation-weighting factors for slow muons is recommended for improved radiation safety.