Dynamic visualization of lung sounds with a vibration response device: a case series
R Phillip Dellinger1, Joseph E Parrillo, Alon Kushnir
1Division of Cardiovascular Disease and Critical Care Medicine, UMDNJ - Robert Wood Johnson Medical School at Camden, Cooper University Hospital, Camden, NJ, USA.
Background:
The field of computer-assisted mapping of lung sounds is constantly evolving and several devices have been developed in this field.
Objectives:
Our objective was to evaluate a new computer-assisted lung sound imaging system, 'vibration response imaging' (VRI), that records and creates a dynamic image of breath sounds. We postulated that the VRI display format would qualitatively and quantitatively reveal breath sound distribution throughout the breathing cycle.
Methods:
Lung sounds were recorded from 5 healthy adults and 14 patients with various respiratory illnesses using VRI. The lung sounds were processed by the VRI software, which incorporates an algorithm to convert breath sounds in the frequency range of 150-250 Hz to a dynamic image and quantitative assessment of breath sound distribution.
Results:
Images and quantifications from recordings of the healthy adults showed distinct patterns for inspiration and expiration. Images and quantifications from the subjects with respiratory illness differed substantially from the images of the healthy subjects. Both healthy and pathological subjects presented some expected characteristics of breath sound distribution.
Conclusions:
The VRI device may provide a new perspective in acoustic imaging and quantification of breath sounds by adding aspects of time analysis and quantification of distribution to existing methods. Further studies will be required in order to establish reliability of repeated recordings and to validate the sensitivity of the system in detecting various lung pathologies.
Related Concept Videos
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.