Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Analysis of Spatio-Temporal Representations for Robust Footstep Recognition with Deep Residual Neural Networks.

IEEE transactions on pattern analysis and machine intelligence·2018
Same author

[Obstructive sleep apnoea syndrome].

Anales de pediatria·2017
Same author

Inhaled nitric oxide in adult patients with acute respiratory distress syndrome.

Farmacia hospitalaria : organo oficial de expresion cientifica de la Sociedad Espanola de Farmacia Hospitalaria·2017
Same author

Digitally balanced detection for optical tomography.

The Review of scientific instruments·2007
Same author

Toward in-cylinder absorption tomography in a production engine.

Applied optics·2005

Related Experiment Video

Updated: Jul 14, 2026

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

Generic-type hierarchical multi digital signal processor system for hard-field tomography.

Sergio Garcia Castillo1, Krikor B Ozanyan

  • 1Sensors, Imaging & Signal Processing Group, School of Electrical Engineering and Electronics, The University of Manchester, Manchester, United Kingdom.

The Review of Scientific Instruments
|June 8, 2007
PubMed
Summary

This study presents a new hierarchical multi-digital signal processor system for parallel processing in hard-field tomography. The system enables high-speed data acquisition and processing for applications like temperature mapping.

More Related Videos

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

Related Experiment Videos

Last Updated: Jul 14, 2026

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time
09:56

Universal Hand-held Three-dimensional Optoacoustic Imaging Probe for Deep Tissue Human Angiography and Functional Preclinical Studies in Real Time

Published on: November 4, 2014

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages
08:46

Using Synchrotron Radiation Microtomography to Investigate Multi-scale Three-dimensional Microelectronic Packages

Published on: April 13, 2016

Area of Science:

  • Engineering
  • Computer Science
  • Physics

Background:

  • Hard-field tomography requires efficient parallel multichannel data acquisition and processing.
  • Existing systems may lack modularity and software-configurable processing.

Purpose of the Study:

  • To design and implement a hierarchical multi-digital signal processor system for advanced tomography applications.
  • To create a modular and expandable tomography system with software-defined data processing.

Main Methods:

  • Development of a hierarchical multi-digital signal processor architecture.
  • Implementation of modular and expandable hardware with software-configured data processing modalities.
  • Utilizing digital lock-in detection for ac measurements and data extraction.

Main Results:

  • Achieved a data frame rate of up to 250 kHz through optimized circuit configuration and data flow management.
  • Successfully demonstrated the system's capabilities in a guided path tomography case study for temperature mapping.
  • Extracted temperature-induced resistance changes from 32 non-interacting transducers.

Conclusions:

  • The developed hierarchical multi-digital signal processor system offers a flexible and high-performance solution for hard-field tomography.
  • The modular design and software configurability allow adaptation to diverse data processing needs.