Surgical Techniques for Catheter Placement and 5/6 Nephrectomy in Murine Models of Peritoneal Dialysis
Published on: July 19, 2018
Increasing fill volume reduces cardiac performance in peritoneal dialysis
Per Ivarsen1, Johan V Povlsen, Jens Dam Jensen
1Department of Renal Medicine C, Aarhus University Hospital, Skejby, Brenstrupgaardsvej 100, 8200 Aarhus N, Denmark. pi@dadlnet.dk
Background:
It is generally accepted that peritoneal dialysis (PD) affects systemic haemodynamics less than haemodialysis, but little is known about changes in haemodynamics during PD. It is unknown if increasing PD volume causes changes in cardiovascular haemodynamics possibly increasing the demand on the heart even during normal daily activities.
Methods:
Fifteen stable PD patients were included in this randomized, controlled, open-label crossover study. After drainage, we measured blood pressure, pulse rate and cardiac output (CO) after 30 min in the supine position. The measurements were repeated 5 min later in an upright position. Subsequently, following fill, the measurements were repeated after 30 min in the supine and 5 min later in the upright position. The two procedures were repeated twice. The fill was either 2 l or 3 l of dialysate. CO was measured with a non-invasive device based on foreign gas rebreathing. Stroke volume (SV) and total peripheral systemic resistance were calculated.
Results:
In the supine position, no difference was found between drained and 2 l fill. With 3 l fill both SV and CO decreased and total peripheral systemic resistance increased, while pulse rate and mean arterial blood pressure remained unchanged. In the upright position, SV and CO decreased and total peripheral systemic resistance increased. Pulse rate and mean arterial blood pressure were unchanged independent of fill volume when compared with the drained situation. During postural change, no significant differences were found between drained and 2 l and 3 l fill.
Conclusion:
The present study showed that cardiac performance decreased when increasing fill volume from 2 to 3 l in the supine position. The decreased cardiac performance was already present after 2 l fill in the upright position and did not change negatively by increasing fill. It was also shown that cardiovascular response from the supine to upright position was preserved.
More Related Videos
06:27A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice
Published on: July 20, 2022
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Peritoneal Dialysis I: Introduction and Procedure
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Peritoneal Dialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Heart Failure Drugs: Diuretics
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...