Monochromatic electron photoemission from diamondoid monolayers

W L Yang1, J D Fabbri, T M Willey

  • 1Geballe Laboratory for Advanced Materials, Stanford University, Stanford, CA 94305, USA.

Science (New York, N.Y.)
|June 9, 2007
PubMed
Summary

Researchers discovered monochromatic electron emission from diamondoid monolayers. This breakthrough offers a novel source of low-energy electrons for advanced technologies like electron microscopy and lithography.

Related Concept Videos

Photoelectric Effect02:26

Photoelectric Effect

When light of a particular wavelength strikes a metal surface, electrons are emitted. This is called the photoelectric effect. The minimum frequency of light that can cause such emission of electrons is called the threshold frequency, which is specific to the metal. Light with a frequency lower than the threshold frequency, even if it is of high intensity, cannot initiate the emission of electrons. However, when the frequency is higher than the threshold value, the number of electrons ejected...
Overview of Electron Microscopy01:25

Overview of Electron Microscopy

The wavelengths of visible light ultimately limit the maximum theoretical resolution of images created by light microscopes. Most light microscopes can only magnify 1000X, and a few can magnify up to 1500X. Electrons, like electromagnetic radiation, can behave like waves, but with wavelengths of 0.005 nm, they produce significantly greater resolution up to 0.05 nm as compared to 500 nm for visible light. An electron microscope (EM) can create a sharp image that is magnified up to 2,000,000X.
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
Atomic Emission Spectroscopy: Instrumentation01:22

Atomic Emission Spectroscopy: Instrumentation

The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers.  Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
The Electrical Double Layer01:30

The Electrical Double Layer

In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
Determination of Crystal Structures01:29

Determination of Crystal Structures

In the late 1800s, the revelation that light extended beyond visible wavelengths led to the discovery of X-rays by Wilhelm Roentgen. Recognized as high-energy electromagnetic radiation with short wavelengths, X-rays prompted exploration into their interaction with crystals. Max von Laue proposed in 1912 that the periodic arrangement of atoms, ions, or molecules in crystals would cause them to diffract X-rays, a hypothesis confirmed through experiments with copper sulfate and zinc sulfide...