Related Experiment Video
Updated: Jul 9, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
The effect of core framework designs on the fracture loads of all-ceramic fixed partial dentures on posterior
Y Kokubo1, M Tsumita, S Sakurai
1Department of Fixed Prosthodontics, Tsurumi University School of Dental Medicine, Yokohama, Japan. kokubo-y@tsurumi-u.ac.jp
Abstract:
This study evaluated the fracture loads of three-unit all-ceramic bridges on implants; the core frameworks of the bridges were made of zirconium oxide. Three core framework designs were fabricated according to the design of the bars between the retainers: (i) straight, (ii) curved in the occlusal direction, or (iii) curved in the gingival direction. A static load was applied at the centre of the pontic, and the mean initial crack and final fracture loads were measured and compared. The core framework curved in the occlusal direction had the highest final fracture loads; there were significant differences (P < 0.05) in the mean final fracture load, whereas initial fracture load, which fractured of veneered porcelain, did not show significant differences among three designs. The all-ceramic bridges on the implants made with Procera zirconium core frameworks had high final fracture load. The core framework design that curved in the occlusal direction helped the framework withstand the occlusal load, which results in reliable prostheses, especially in the molar region.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Design of Prismatic Beams for Bending
Tooth Anatomy
The Crown, Neck, and Root
The visible part of the tooth is referred to as the crown. It's covered by enamel, the hardest substance in the human body. The crown is uniquely shaped for each type of tooth, allowing for different functions such as cutting, tearing, or grinding food.
Veneer
Other veneering techniques include plain-slicing, quarter-slicing, and rift-slicing. These...
Bonding and Strength of Aggregate