The effect of multidirectional mechanical vibration on peripheral circulation of humans
C Button1, N Anderson, C Bradford
1Human Performance Centre, School of Physical Education, University of Otago, Dunedin, New Zealand. chris.button@otago.ac.nz
Abstract:
The physiological response of humans to vibration has intrigued researchers for some time, and recently in relation to its potential as a non-pharmacological means to improve peripheral blood flow. A new vibration device [Arapal Technologies Ltd (ATL), Christchurch, New Zealand] for pain relief that purportedly delivers multidirectional vibration waveforms, has been developed. The aim of the study was to quantify the effect of 30 min of mechanical vibration (60 Hz) using two ATL massage devices concurrently upon local peripheral blood flow in healthy humans. On the basis of past work it was expected that acute exposure of the body to the vibratory stimulus would increase local peripheral blood flow. In a randomized cross-over design, mean blood flow (MBF) to the calf was measured using venous occlusion plethysmography before, during 3 min and after 30 min exposure to the vibratory devices or placebo (non-vibratory) devices. Statistical analysis revealed no consistent differences between conditions and considerable individual variability. The MBF increase tended to be higher in the vibration condition than the placebo condition (P=0.16, 95% likely range=-14.4% to 82.2%), the mean increase from resting blood flow at the post-test was 26+/-49% in the vibration condition and 12+/-39% in the placebo condition. It took approximately 22 min of exposure to the vibratory stimulus to elicit peak blood flow (18 min with the placebo). Improvements in local blood flow may be beneficial in the therapeutic alleviation of pain or other symptoms resulting from acute or chronic musculoskeletal injuries.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Peripheral Artery Disease I: Introduction
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...