Related Experiment Video
Updated: Jul 14, 2026

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand
Published on: September 8, 2016
Separation of dialkyl sulfides by metallo-mesogenic stationary phases for complexation gas chromatography
Jian-Lian Chen1, Chuen-Ying Liu
1Department of Occupational Safety and Health, Chung Shan Medical University, Taichung, Taiwan. cjl@csmu.edu.tw
Abstract:
A copper mesogenic side-chain polymer (P-C(15)CuC(18)) was cross-linked onto the capillary wall as a stationary film for gas chromatography (GC) separation of alkyl sulfides. These organic sulfides are of interest for their large health impact because of their wide range of volatiles and high reactivities toward metals. Different GC parameters for optimal separation efficiency are discussed for use with a mesogenic polymer column along with flame photometric detection (FPD). Both the carrier gas flow-rate and column temperature were studied to determine the relationship of plate height to the chemical structure of the solutes, as well as to determine the morphology of the mesogenic polymer. Van 't Hoff plots show phase transitions of the stationary mesophase as the column temperature was varied. The results reveal that the separation mechanism might be based on ligand exchange and polarity interaction between the analytes and the stationary phase, with the vapor pressure of the analytes also being important. The former interaction dominates in the lamellar crystalline phase and the latter interaction dominates in the hexagonal columnar-discotic phase. With high reproducibility for retention time (RSD< or =0.37%) and for peak area (RSD< or =5.16%), the GC-FPD system produced linear calibration graphs (r> or =0.9918) for the determination of 13 sulfides with a detection limit below 2.5 ng.
More Related Videos
Related Concept Videos
Extraction: Advanced Methods
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...