Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy
S Modi1, A W B Stanton, W E Svensson
1Cardiac and Vascular Sciences, St George's Hospital Medical School, University of London, Cranmer Terrace, London SW17 0RE, UK.
Abstract:
Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast cancer treatment-related lymphoedema (BCRL) such as its delayed onset. A new method was developed to measure human lymphatic contractility non-invasively and test the hypothesis of contractile impairment. 99mTc-human IgG (Tc-HIG), injected into the hand dermis, drained into the arm lymphatic system which was imaged using a gamma-camera. Lymph transit time from hand to axilla, ttransit, was 9.6+/-7.2 min (mean+/-s.d.) (velocity 8.9 cm min(-1)) in seven normal subjects. To assess lymphatic contractility, a sphygmomanometer cuff around the upper arm was inflated to 60 mmHg (Pcuff) before 99mTc-HIG injection and maintained for>>ttransit. When Pcuff exceeded the maximum pressure generated by the lymphatic pump (Ppump), radiolabelled lymph was held up at the distal cuff border. Pcuff was then lowered in 10 mmHg steps until 99mTc-HIG began to flow under the cuff to the axilla, indicating Ppump>or=Pcuff. In 16 normal subjects Ppump was 39+/-14 mmHg. Ppump was 38% lower in 16 women with BCRL, namely 24+/-19 mmHg (P=0.014, Student's unpaired t test), and correlated negatively with the degree of swelling (12-56%). Blood radiolabel accumulation proved an unreliable measure of lymphatic pump function. Lymphatic congestion lymphoscintigraphy thus provided a quantitative measure of human lymphatic contractility without surgical cut-down, and the results supported the hypothesis of lymphatic pump failure in BCRL.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Lymphatic Vessels and Lymph Transport
This one-way system allows fluids, solutes, and even pathogens to enter but prevents their return to the intercellular spaces.
Development of the Lymphatic System
The first lymph sacs to form are the paired jugular lymph sacs located at the junction of the internal jugular and subclavian veins. From these sacs, lymphatic capillary plexuses extend to the thorax, upper limbs, neck, and head, eventually forming lymphatic vessels. Each jugular lymph sac maintains a...
Detailed Structure and Function of Lymph Nodes
From a histological perspective, lymph nodes can be split into two main areas: the superficial cortex and the deep medulla. The outer cortex is populated by dendritic cells, macrophages, and B lymphocytes, which are densely packed into follicles. When these B-lymphocytes are presented...