Related Experiment Video
Updated: Jul 14, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Comparison of 2- and 3-dimensional exercise echocardiography for the detection of coronary artery disease
Jesús Peteiro1, Pablo Piñon, Ruth Perez
1Unit of Echocardiography and Department of Cardiology, Juan Canalejo Hospital, A Coruña University, A Coruña, Spain. pete@canalejo.org <pete@canalejo.org>
Background:
Although 3-dimensional echocardiography (3DE) has been applied during dobutamine echocardiography it has not been used during exercise echocardiography. We sought to compare feasibility and accuracy of 3DE and 2-dimensional echocardiography (2DE) during exercise echocardiography.
Methods:
100 patients underwent peak and postexercise (PEx) 2DE and 3DE on separate days. Coronary artery disease was detected in 58 patients. A quality score was calculated by assigning 0 to 3 points to each wall (apicoseptal, posterolateral, anterior, inferior).
Results:
Feasibility of peak 2DE, peak 3DE, PEx 2DE, and PEx 3DE was 99%, 92%, 100%, and 95%, respectively (2DE at peak or PEx vs peak 3DE, P < .05). Agreement between 2DE and 3DE was 82% at peak (kappa = 0.62) and 78% at PEx (kappa = 0.55). Quality score less than 2 was seen in 4% of the walls with peak 2DE, in none with PEx 2DE, in 18% by peak 3DE, and in 14% by PEx 3DE. The mean quality score was lower with 3DE at peak and at PEx (2.4 +/- 0.9 vs 2.9 +/- 0.3; and 2.5 +/- 0.8 vs 3.0 +/- 0.1, both P < .0001). Acquisition time was shorter with 3DE at peak and PEx (22 +/- 8 vs 43 +/- 14 seconds; and 15 +/- 5 vs 31 +/- 14 seconds, both P < .0001). Sensitivity of peak 2DE, peak 3DE, PEx 2DE, and PEx 3DE was 84%, 78%, 71%, and 58%, respectively (P < .05 vs peak 3DE and peak 2DE). Specificity was 76%, 73%, 93%, and 88%, respectively. Accuracy for peak 2DE was 81% (area under the curve [AUC] 0.81, 95% confidence interval [CI] = 0.71-0.91); for peak 3DE was 76% (AUC 0.76, 95% CI = 0.65-0.86); for PEx 2DE was 80% (AUC 0.84, 95% CI = 0.75-0.92); and for PEx 3DE was 71% (AUC 0.73, 95% CI = 0.62-0.83).
Conclusions:
Three-dimensional echocardiography during exercise is comparable with 2DE in terms of sensitivity and specificity but feasibility is lower.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Cardiac Catheterization III: Left Heart Catheterization