Instrument accuracy and reproducibility in measurements of pulmonary function
Robert L Jensen1, John G Teeter, Richard D England
1Pulmonary Laboratory, LDS Hospital and University of Utah, Eighth Ave and C St, Salt Lake City, UT 84143, USA. ldrjens1@ihc.com
Background:
The objective of the study was to quantify the accuracy and reproducibility of five commercially available pulmonary function test (PFT) instruments (Collins CPL [Ferraris Respiratory; Louisville, CO]; Morgan Transflow Test PFT System [Morgan Scientific; Haverhill, MA]; SensorMedics Vmax 22D [VIASYS Healthcare; Yorba Linda, CA]; Jaeger USA Masterscreen Diffusion TP [VIASYS Healthcare]; and Medical Graphics Profiler DX System [Medical Graphics Corp; St. Paul, MN]) that are associated with spirometry and the measurement of pulmonary diffusing capacity.
Methods:
In a multifactor, single-center, repeated-measures, full factorial 90-day study, a pulmonary waveform generator and a single-breath simulator of diffusing capacity of the lung for carbon monoxide (Dlco) were used to perform simulations of FVC and Dlco maneuvers. Accuracy was assessed as the difference between the observed and simulated values. Reproducibility was determined as the coefficient of variation of all measurements made during the study.
Results:
All instruments demonstrated a high degree of accuracy in the measurement of FVC and FEV(1). Overall, the accuracies associated with the measurement of peak flow, forced expiratory flow, mid-expiratory phase, and diffusing capacity were generally lower and more variable among the instruments tested. The coefficients of variation of Dlco measurements over 90 days were higher than those observed for spirometry.
Conclusions:
This study demonstrates the feasibility of assessing the accuracy and reproducibility of modern PFT instruments using simulation testing. Our results provide an assessment of the component of PFT accuracy and reproducibility that is due to instrumentation alone.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Uncertainty in Measurement: Reading Instruments
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...