Objective:
To audit a single center consecutive series of infrapopliteal composite bypasses with second generation glutaraldehyde stabilized human umbilical vein.
Design:
Retrospective study.
Patients:
From January 1996 to July 2006 89 femoro-distal bypasses were constructed in 85 patients with HUV and residual vein segments as composite grafts in the absence of sufficient length of autologous vein.
Methods:
All patients with infrainguinal bypass operations were registered prospectively. Bypasses to infrapopliteal arteries performed with HUV-composite grafts were reviewed for graft patency, limb salvage, patient survival and possible biodegeneration of the HUV.
Results:
Early graft thrombosis was noted in 21.3%, necessitating revision surgery. Primary, primary assisted and secondary patency rates were 35%, 40% and 42% respectively, with a limb salvage rate of 87% after 5 years. Graft infection occurred in 7 limbs. Aneurysmal HUV graft degeneration was not detected by duplex scanning.
Conclusion:
HUV-composite bypasses provide acceptable patency and favorable limb salvage rates. Patency was similar to previous series using PTFE-composite bypasses but was significantly inferior to vein bypass. Possible biodegradation of the HUV grafts seems to be of minor clinical relevance.