Related Experiment Video
Updated: Jul 14, 2026

Sulfate Separation by Selective Crystallization with a Bis-iminoguanidinium Ligand
Published on: September 8, 2016
[Determination of standard value of sulfate standard solution by Ion chromatography]
Liping Zhang1, Zhi Xing, Lu Feng
1Chemistry Department of Baotou Normal College of Inner Mongolia University of Science and Technology, Baotou 014030, China. lpzhang@chen.tsinghua.edu.cn
Abstract:
A method for precise quantitation of sulfate in standard solutions by ion chromatography with suppression conductivity detection has been developed. The separation of sulfate was conducted on an IonPac AS19 anion exchange column (2 mm x 250 mm) with NaOH solution as isocratic eluent. The injection volume was 25 microL. An orthogonally designed experiment was carried out to evaluate the effects of the experiment factors, such as column temperature, concentration of eluent NaOH, flow-rate of the eluent, and cell temperature. The optimal chromatographic conditions obtained were as follows: column temperature, 30 degrees C; NaOH concentration, 30 mmol/L; flow-rate of the eluent, 0. 25 mL/min; cell temperature, 35 degrees C. The detection limit (3sigma) was 0. 005 mg/L. On the level of 4. 5 mg/L sulfate, the relative standard deviation (RSD) was 0. 44% (n = 8). The linear range of calibration curve was 1. 0 - 50. 0 mg/L. The reliability of method was shown by the evaluation of stability of calibration curves. The variance analysis showed that the intercept and slope of 7 calibration curves were controlled statistically in the desired range. The reliability of method was shown by quality control samples, where RSD and relative error were less than 0. 9%, and 0. 8%, respectively. Average recovery of standard addition was 95. 5% - 105%. The method has been applied to the quantitation of sulfate in standard solution.
More Related Videos
06:27Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
10:09A Straightforward Method for Glucosinolate Extraction and Analysis with High-pressure Liquid Chromatography (HPLC)
Published on: March 15, 2017
Related Concept Videos
Ion-Exchange Chromatography
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitation Titration Curve: Analysis
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Ionic Strength: Overview
Ionic Strength: Effects on Chemical Equilibria
In this solution, the primary cation—the calcium...