Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
Reliability-based rearrangement of ECG automated interpretation chain
1AGH University of Science and Technology, Krakow, Poland. august@agh.edu.pl
Objective:
Sequences of electrocardiogram (ECG) interpretation procedures from various manufacturers of ECG-dedicated software were studied in aspect of data flow and reliability of intermediate results. The results motivated us to design a new system architecture considering error propagation issues on subsequent stages of ECG processing and reducing the data stream on initial stages.
Methods:
The proposed architecture has network topology and consists of the procedures interconnected by data buses. Each node and isolated sub-networks were tested against the MIT-BIH, CSE standard databases and described by the incorrect result probability and data reduction efficiency. The optimized solution considers also the probability of the procedure use and probability of useless outcome. Best performing network was selected and compared to the original sequential interpretation chain.
Results:
The optimized architecture moves reduction-effective functions to the front of the processing chain, reduces the cumulative error propagation by parallel use of multiple short processing chains and reduces the interpretation processing time and the required computational power. Depending on interpretation domain, the reduction of outcome relative inaccuracy was up to 87% (from 2.8% to 1.5%) for pacemaker pulse detection or 70% (from 6.3% to 3.7%) for wave axes determination.
Conclusion:
Significant improvements in automated ECG interpretation were achieved by rearrangement of processing chain only, without any change in processing methods. Reduction of the data stream at early processing stages is particularly advantageous in wireless interpretation system, since task sharing involves minimum exploitation costs.
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Dysrhythmias V: Evaluating Dysrhythmias