Treatment of a fractured ultraflex stent causing tracheal stenosis
Takeshi Mori1, Hiroaki Nomori, Masakazu Yoshioka
1Department of Thoracic Surgery, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
Abstract:
We report on a case of a fractured Ultraflex stent after placement for malignant tracheal stenosis. The patient was a 49-year-old female with adenoid cystic carcinoma of the trachea causing airway stenosis. She was treated by non-covered Ultraflex stent followed by chemoradiotherapy. Twenty months after stent placement, more than half of the distal end of the stent was fractured and caused airway stenosis, while there was no tumor regrowth. After dilation by balloon and bougienage using an endotracheal tube, an additional non-covered Ultraflex stent was placed within the first one, resulting in successful dilation. The patient is now well without any problem with the stent, 12 months after the second stent placement.
More Related Videos
Related Concept Videos
Mitral Stenosis IV: Nursing Management
Mitral Stenosis III: Medical Management
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis I: Introduction
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...