Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses
Aaron Waite1, Nathan Faulkner, Randall J Olson
1Department of Ophthalmology and Visual Sciences, University of Utah Health Sciences Center, Salt Lake City, Utah, USA.
Purpose:
To study glistenings in single-piece AcrySof (models SA60 and SN60; Alcon, Fort Worth, Texas, USA) intraocular lenses (IOLs).
Design:
Observational, longitudinal study.
Methods:
Consecutive patients with the SA60 were examined at 12, 24, and 36 months after surgery; those with the SN60 were examined 12 months after surgery. Best-corrected logarithm of the minimum angle of resolution visual acuity, glare testing, contrast sensitivity, and wavefront analysis were performed. Any patient with pathologic features likely to impact visual quality was eliminated. All IOLs were photographed, and glistenings were analyzed for size and density by a computer program.
Results:
All IOLs had glistenings, and neither size, density, nor severity index (size x density) correlated with acuity, glare testing, or wavefront analysis results. High spatial resolution contrast acuity (patch D) had a borderline correlation (P = .06) with severity index, as did progress over time (P = .04).
Conclusions:
All IOLs studied had glistenings. High spatial resolution contrast sensitivity impact and severity progression over time deserve further study.
More Related Videos
06:55Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
04:59Rotating the Intraocular Lens to Prevent Posterior Capsular Opacification in Cataract Surgeries
Published on: July 7, 2023
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment