Hepatic entropy and uniformity: additional parameters that can potentially increase the effectiveness of contrast
B Ganeshan1, K A Miles, R C D Young
1Department of Engineering & Design, University of Sussex, Brighton, UK. b.ganeshan@sussex.ac.uk
Aim:
To determine how hepatic entropy and uniformity of computed tomography (CT) images of the liver change after the administration of contrast material and to assess whether these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion.
Materials And Methods:
Hepatic attenuation, entropy, uniformity, and perfusion were measured using multi-phase CT following resection of colorectal cancer. Based on conventional CT and fluorodeoxyglucose positron emission tomography, 12 patients were classified as having no evidence of malignancy, eight with extra-hepatic tumours only, and eight with metastatic liver disease.
Results:
Hepatic attenuation and entropy increased after CM administration whereas uniformity decreased. Unlike hepatic attenuation, entropy and uniformity changed maximally in the arterial phase. No significant differences in hepatic perfusion or attenuation were found between patient groups, whereas arterial-phase entropy was lower (p=0.034) and arterial-phase uniformity was higher (p=0.034) in apparently disease-free areas of liver in patients with hepatic metastases compared with those with no metastases.
Conclusion:
Temporal changes in hepatic entropy and uniformity differ from those for hepatic attenuation. By reflecting the distribution of hepatic enhancement, these additional parameters are more sensitive to tumour-related changes in the liver than measurements of hepatic attenuation or perfusion.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...