Recent accomplishments in the field of enantiomer separation by CEC

Beatrix Preinerstorfer1, Michael Lämmerhofer

  • 1Christian Doppler Laboratory for Molecular Recognition Materials, Institute of Analytical Chemistry and Food Chemistry, University of Vienna, Vienna, Austria.

Electrophoresis
|July 4, 2007
PubMed

Related Concept Videos

Racemic Mixtures and the Resolution of Enantiomers02:30

Racemic Mixtures and the Resolution of Enantiomers

A racemic mixture, or racemate, is an equimolar mixture of enantiomers of a molecule that can be separated using their unique interaction with chiral molecules or media. Racemic mixtures are denoted by the (±)- prefix. This ‘optical rotation descriptor’ applies to the whole solution of a racemic mixture rather than a specific stereoisomer. Enantiomers typically have the same physical and chemical properties. Hence, they are not easily separable. However, enantiomers can exhibit different...
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Stereochemical Effects of Enolization01:12

Stereochemical Effects of Enolization

The chiral α-carbon of the carbonyl compound is the stereocenter of the molecule. As shown in the figure below, when such a carbonyl compound undergoes racemization under an acidic or basic condition, an achiral enol is formed.
Naming Enantiomers02:21

Naming Enantiomers

The naming of enantiomers employs the Cahn–Ingold–Prelog rules that involve assigning priorities to different substituent groups at a chiral center. Each enantiomer, being a distinct molecule, is assigned a unique name by the Cahn–Ingold–Prelog (CIP) rules, also called the R–S system. The prefix R- or S- attached to the chiral centers in an enantiomer is dependent on the spatial arrangement of the four substituents on the chiral center. The R–S system essentially comprises three steps:...
Optimizing Chromatographic Separations01:15

Optimizing Chromatographic Separations

Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...